The EEG Suite and the Physiology Suite take full advantage of the latest functions and features of our powerful multimedia biofeedback software, like DVD movie control, and provide complete control over your entire clinical process, from assessment, to training, to reporting and demonstrating outcome. Both Suites will run with the ProComp Infiniti, ProComp +, ProComp 5 and ProComp 2 encoders and many of the screens and scripts come in versions for one and for two monitor configurations.


A full range of clinical tools

Each suite includes all the display screens you need for:

  • Verifying signal quality and adjusting sensor placement
  • Monitoring and assessing physiological functions
  • Recording biofeedback training sessions
  • Reviewing recorded data for the purpose of artifact rejection
  • Generating session reports and demonstrating the learning curves

Standard physiology based protocols

The Physiology Suite includes all the tools you need for multi-modality physiological assessments and over 80 display screens for training with standard physiological sensors including heart rate with EKG or blood volume pulse (BVP), electromyography (EMG), skin conductance, temperature and respiration. Using the Physiology suite, you can train self-regulation with physiological biofeedback protocols that include relaxation with EMG, temperature or skin conductance, heart rate variability with respiration and EKG or BVP and abdominal/thoracic breathing. The suite also features a full-length relaxation exercise script with a recorded audio track guiding the client through deep relaxation and progressive recovery.

For your clinical assessments and follow-ups, the suite incorporates pre and post-training baseline assessment scripts and a 7-activity Stress Assessment script which takes the client through three cycles of stress induction and relaxation steps, including color words, math task and stressful event recall. Using the stress assessment script, you can rapidly identify any hyper- or hypo-reactivity in any of the recorded modalities.


Physiology Suite features

  • A skin-conductance driven relaxation script with audio induction track
  • A full range of heart rate variability training screens
  • Simple feedback screens with auto or manual thresholds
  • Single and dual-monitor display screens
  • Real-time epoch statistics for instant trend graphing

The EEG Suite and the Physiology Suite take full advantage of the latest functions and features of our powerful multimedia biofeedback software, like DVD movie control, and provide complete control over your entire clinical process, from assessment, to training, to reporting and demonstrating outcome. Both Suites will run with the ProComp Infiniti, ProComp +, ProComp 5 and ProComp 2 encoders and many of the screens and scripts come in versions for one and for two monitor configurations.


A full range of clinical tools

Each suite includes all the display screens you need for:

  • Verifying signal quality and adjusting sensor placement
  • Monitoring and assessing physiological functions
  • Recording biofeedback training sessions
  • Reviewing recorded data for the purpose of artifact rejection
  • Generating session reports and demonstrating the learning curves

Standard and user-defined protocols

The EEG Suite offers over 80 display screens for many standard EEG protocols, including an outstanding alpha-theta training screen and a number of template-style screens for training with 3, 6 or 10 user-defined EEG bands. The standard protocols can be used for training alpha amplitude (range), alpha peak frequency, alpha theta, beta amplitude, SMR amplitude, theta beta, theta SMR and wide band inhibit.

The EEG Suite also provides you with advanced tools for assessment and follow-up, including pre and post-training baseline assessment scripts and a 4-activity EEG assessment script for recording baselines with eyes-open, eyes-closed, and during a mental challenge and a listening task.


Include physiological components

The EEG suite incorporates a set of EEG screens which combine most useful physiological feedback elements. You can, for example, run a neurofeedback session, training 3 user-defined EEG bands, and do basic heart rate variability biofeedback at the same time or train EEG with EMG, skin conductance and temperature.


EEG Suite features:

  • On-the-fly cut-off frequency adjustments
  • In session impedance checking
  • Manual and auto threshold instruments with user-specified target percentage of time
  • Single and dual-monitor display screens
  • Real-time epoch statistics for instant trend graphing

CardioPro Infiniti is a specialized off -line analysis module which brings advance d heart rate variability (HRV) analysi s capabilities to the BioGraph Infiniti platform. It complements any physiological biofeedback suite (such as the Physiology suite) by providing sophisticated data analysis methods that were only previously available in very specialized software packages such as Thought Technology's CardioPro software.


Easy access to BioGraph sessions

The module accesses BioGraph Infiniti's client database directly and is capable of processing open display and script sessions that were recorded with either an electrocardiograph (EKG) or blood volume pulse (BVP) sensor to generate session specific statistical analysis. (The module is also compatible with Thought Technology's specialized receiver for the T31 Transmitter belts from Polar.)


Easy normalizing of IBI data

The module provides advanced tools for normalizing and analysing inter-beat interval (IBI) data. The statistical analyses follow the guidelines published in 1996 by the HRV Task Force. A powerful IBI editor offers both automatic and manual normalization functions to help you rapidly remove artifacts caused by extra beats, missed beats or premature atrial/ventricular contractions (PAC or PVC) using three standard operations, ADD, SPLIT and AVERAGE.


Easy analysis of peripheral physiological data

The module also provides all the editing and statistical analysis functions you need for removing artifacts from other physiological measures such as respiration, skin conductance, temperature and electromyography (EMG).


Easy reporting options

Once recorded data is normalized and artifacts have been rejected, the module generates a thorough statistical analysis which you can review, prior to printing it out. The module's ability to reprocess your data with epoch durations of either 1, 3, 5 or 10 minutes adds unmatched flexibility to your analysis. The graphical analysis also provides epoch by epoch 2D and 3D power spectrum views as well as a standard tachogram and Poincar 'e plot. Once you are satisfied with the data analysis, you can rapidly generate reports as either Microsoft Word or Excel documents and export IBI data and statistical tables to text files.

The Rehab Suite combines Thought Technology's powerful BioGraph Infiniti software with specialized protocols, screens, animations and statistics, designed to provide customized physical rehab treatment for your patients. Its flexibility in all aspects of its use, from recording options to protocols and sound and visual feedback, will enable you to reach new levels of treatment.

Simply click on 'Quick Start', choose your patient and training program, and start rehab treatment.


The Rehab Suite works on two series of hardware platforms

The Rehab Suite combines Thought Technology's powerful BioGraph Infiniti software with specialized protocols, screens, animations and statistics, designed to provide customized physical rehab treatment for your patients. Its flexibility in all aspects of its use, from recording options to protocols and sound and visual feedback, will enable you to reach new levels of treatment. Simply click on 'Quick Start', choose your patient and training program, and start rehab treatment.

Pro/Flex Series

Myotrac Series

PRO/FLEX SERIES CONTENT

Thought Technology introduces new additions to its Rehab Suite: ProComp5, ProComp Infiniti andFlexComp Infiniti.

The Rehab Suite proposes various assessment and training protocols with very helpful guidelines for beginners, as well as experts.

It combines dynamic graphics, with analysis and reporting functions, the result of 30 years of experience in Biofeedback.

Simply click on 'Quick Start', choose your patient and training program, and start treatment.

Depending on the hardware of your choice, the Suite includes:

  • Surface Electromyography (SEMG)
  • Range of Motion (ROM)
  • Muscle Testing
  • Algometry
  • Respiration
  • Heart Rate Variability (HRV)
  • Skin Conductance and Peripheral Temperature

Clinically Relevant Documentation

The Rehab Suite has been designed by and for physical therapists. It comes with a clinical guide, explaining the general concepts of each modality.


Comprehensive View of Patient Rehabilitation

The Rehab Suite provides a wide variety of assessment protocols for:

  • Dynamic and Static SEMG Assessment
  • Dynamic and Static Range of Motion
  • Muscle Testing with or without SEMG
  • Algometry

Benefits of Biofeedback Training

By providing the patient, and their therapist, access to muscular information about which they are both generally unaware, biofeedback provides accurate, reliable, measurable, objective data to augment and support the subjective reporting of the patient and observations of the therapist.

Muscle activity can be recorded and used to provide both instant feedback for motivation, learning and improved rehabilitation and display trend reports over sessions, to demonstrate with objective numbers, the value of the therapy both to the patient and the service provider or payer.


Audio Visuals Can Make A World of Difference

Comprehensive use of animations and sounds provide relevant rehabilitation goals and activities to keep patients motivated at the highest level:

  • Single and dual channel line graphs, bar graphs and digital displays.
  • Spectral displays
  • Median frequency for muscle fatigue assessment
  • Above and below threshold sound feedback options
  • A wide variety of sounds and music
  • Animations
  • Video
  • Templates include a range of simple to challenging visual traces for your patients to follow.

The Suite comes with a number of pre-made templates - or you can create your own.

MYOTRAC SERIES CONTENT

Our MyoTrac3 and MyoTrac Infiniti are used as an essential part of many therapeutic treatments and clinical assessment protocols for incontinence and muscle rehabilitation.

They allow you to measure high-resolution surface electromyography (SEMG).

The Rehab Suite proposes various SEMG assessment and training protocols with very helpful guidelines for beginners, as well as experts.

It combines dynamic graphics, with analysis and reporting functions, the result of 30 years of experience in Biofeedback.

Simply click on 'Quick Start', choose your patient and training program, and start treatment.

The Reaction Time Suite includes both continuous performance testing (CPT) and real sports reaction time training.


Continuous Performance Testing (CPT)

The Reaction Time Suite takes standard CPT protocols (single, variable and choice) to the next level by combining reaction time data with time-locked EEG and physiology data, to allow direct linkage of response type to mind and body activity. This allows analysis of individual events or categorized group averaged data, to compare EEG, EMG and physiology during correct and incorrect responses, or errors of omission and errors of commission. The suite also includes training capabilities and offers unprecedented accuracy.


Sports Reaction Time Training

The real sports reaction time protocols are designed for biofeedback training in sports that demand quick reactions to trigger events. It includes screens for baseball, tennis, soccer, track and field, ice hockey and more to train for higher batting averages, better serve returns, more accurate penalty kicks, faster starts, and higher face-off percentages. Features use of push buttons, foot pedals and even raw EMG sensors, to simulate real sports actions by using EMG from muscle contractions to respond to events! Highly accurate, time-locked EEG, physiology and EMG allow in-depth analysis of mind and body activity during sports reaction time training.


Reaction Time Suite features:

  • Continuous performance testing (CPT) with single, variable and choice protocols
  • Time-locked EEG, EMG and physiology with event by event or group averaged analysis
  • Training component
  • Real-sports scenarios and protocols
  • The first of its kind: EMG-triggered responses
  • Highly accurate hardware-based timing
  • Programmable audio and visual events
  • Integrated web cam with frame-by-frame review functionality
  • Review and report screens, full statistics and trend graphs for comparison across sessions
  • Quick start favourites for fast, easy session recording

Clinically Relevant Documentation

The Rehab Suite has been designed by and for physical therapists. It comes with a clinical guide, explaining the general concepts of each modality.


Comprehensive View of Patient Rehabilitation

The Rehab Suite provides a wide variety of assessment protocols for:

  • Dynamic and Static SEMG Assessment
  • Dynamic and Static Range of Motion
  • Muscle Testing with or without SEMG
  • Algometry

Benefits of Biofeedback Training

By providing the patient, and their therapist, access to muscular information about which they are both generally unaware, biofeedback provides accurate, reliable, measurable, objective data to augment and support the subjective reporting of the patient and observations of the therapist.

Muscle activity can be recorded and used to provide both instant feedback for motivation, learning and improved rehabilitation and display trend reports over sessions, to demonstrate with objective numbers, the value of the therapy both to the patient and the service provider or payer.


Audio Visuals Can Make A World of Difference

Comprehensive use of animations and sounds provide relevant rehabilitation goals and activities to keep patients motivated at the highest level:

  • Single and dual channel line graphs, bar graphs and digital displays.
  • Spectral displays
  • Median frequency for muscle fatigue assessment
  • Above and below threshold sound feedback options
  • A wide variety of sounds and music
  • Animations
  • Video
  • Templates include a range of simple to challenging visual traces for your patients to follow.

The Suite comes with a number of pre-made templates - or you can create your own.

The Continence Suite for MyoTrac-Infiniti U-Control Clinical and MyoTrac3 combines Thought Technology's powerful BioGraph Infiniti software with specialized protocols, screens, animations and statistics, designed to provide customized clinical treatment for your patients. Its flexibility in all aspects of its use, from recording options to protocols and sound and visual feedback, will enable you to reach new levels of treatment. Simply click on 'Start Session', choose your patient and training screens, and start treatment. For subsequent training sessions, the patient's screens and other settings are loaded from the prior session.


Benefits of SEMG Biofeedback

By providing the patient, and their therapist, access to muscular information about which they are both generally unaware, SEMG biofeedback provides accurate, reliable, measurable, objective data to augment and support the subjective reporting of the patient and observations of the therapist.

The microvolt values (millionths of a volt) measurements of muscle activity can be recorded and used to provide both instant feedback for motivation, learning and improved rehabilitation and display trend reports over sessions, to demonstrate with objective numbers, the value of the therapy both to the patient and the service provider or payer.


Comprehensive View of Patient Rehabilitation

The Continence Suite has been designed to aid in the treatment of incontinence. Most incontinence problems can be improved by biofeedback. Patients can acquire more control over their pelvic muscle strengthening, reducing excessive muscle activity or using the muscle appropriately.

The Suite proposes various screens and scripts for:

  • Perineal Control
  • Controlled perineal contraction
  • Held perineal contraction
  • Pelvic floor hypertonicity
  • Pelvic floor hypotonicity
  • Postpartum perineal tonicity
  • Relaxation of perineal muscles
  • Stress incontinence
  • and more...

Audio Visuals Can Make A World of Difference

Comprehensive use of animations and sounds provide relevant rehabilitation goals and activities to keep patients motivated at the highest level:

  • Single and dual channel linegraphs, bargraphs and digital displays
  • Above and below threshold sound feedback options
  • A wide variety of sounds and music controlled by SEMG
  • Animations - custom animations for pediatrics
  • Video/DVD

Feedback Screens

Created for simplicity and functionality in two formats: pre-defined protocols or open display monitoring. The general SEMG screens provide flexible use with a variety of muscle groups. The screens are further divided into Rehabilitation, Relaxation and Expert groupings, for more specific treatment.


Assessment Scripts (Protocols)

These protocols are a quick and easy way to evaluate your patients.


Training Scripts (Protocols)

An extensive set of scripts geared to the treatment of incontinence. The suite provides work-rest or continuous exercise protocols containing templates of varying degrees of difficulty. Allows you to build training programs suited to your patient's individual needs.


Customize your reports

Easily editable reports provide valuable information for third party payers and patient files. Editing features include:

  • Artifact rejection.
  • Statistics on part or all of the session.
  • The ability to save the statistics for clinical reports.
  • Customizing your documents with your clinic's name and information.

Document Your Patient's Progress with a Variety of Trending Options

Trend reporting allows you to graphically and statistically chart a patient's progress between or within sessions.


Templates

Templates include a range of simple to challenging visual traces for your patients to follow. The Suite comes with a number of pre-made templates - or you can create your own.

The BioGraph Infiniti DynaMap Suite, combined with any of four Thought Technology encoders; FlexComp Infiniti, ProComp Infiniti, ProComp+, or ProComp2, lets you record, replay and review 2-10 channel SEMG monitoring and biofeedback sessions. Over 100 screens display SEMG readings combined with other physiological signals. A key feature is live video, which enhances the review of data enabling one to view the video display while pinpointing a moment in time for statistics for each measure. Dual monitor screens also play a key role in the software, allowing the client to view what is required for feedback and the clinician to view the actual data. The BioGraph Infiniti software also lets you edit the existing screens and create new ones of your own.


DynaMap for the FlexComp Infiniti provides 7 channel sets and 57 screens for high resolution and accurate multi-channel SEMG data-acquisition.

The 7 channel sets allows you several choices: connect up to 10 MyoScan-Flex sensors for raw SEMG recording, a combination of 6 MyoScan-Flex Sensors and 4 Goniometers, 6 MyoScan and 2 Goniometers, 6 MyoScan with 2 Force Sensors, 10 Force Sensors, 10 Goniometers, 2 MyoScan-Flex with EKG, Temperature and Skin Conductance for SEMG and peripheral biofeedback. On-board Compact Flash memory gives you the capability to save data directly to the encoder for real life assessments away from the office or lab.


DynaMap for the ProComp Infiniti includes 7 channel sets and 48 screens for multi-channel raw and RMS SEMG combined with up to 6 other physiological measures.

Screens include exciting new 3-D graphics of animated figures that work with the client. As the client moves the animation moves! In addition there are screens to look at the interplay of median frequency and RMS data between bilateral sites. The raw EMG signals can be displayed raw or, as RMS in line graphs and bar graphs as well as 2-D and 3-D spectral displays synchronized with video.


DynaMap for the ProComp+ encoder includes 7 channel sets and 37 screens for 8-channels of SEMG or a mix of 2 channels of SEMG with up to 6 other physiological measures.

Build your own screens using one of our comprehensive channel sets, which includes physical and virtual (including statistics) channels or use the Developer Tools to make changes to the existing channel set to meet your needs. Each of the 7 different channel sets allows for a different use of the ProComp+.


Stress Control Suite

The Stress Control Suite is a 2-modality mini-suite that can be used to teach clients to recognize the physiological symptoms of stress, and increase self-regulation efficiency.

  • Teach classic, effective relaxation methods for self-regulation
  • Monitor physiological stress response through arousal and peripheral temperature
  • Protocols for a stress test, guided relaxation, breathing relaxation, binaural beat relaxation, and open session training
  • 5-Activity Stress Excel Report quickly shows the arousal level of the client during stressor activities as measured against the baseline

Software / Menu

Home


Contact


Biograph Infiniti


Application Suites


Developer Tools

Software / QuickLinks

A full range of clinical tools


Standard physiology based protocols


Physiology Suite features


Standard and user-defined protocols


Include physiological components


EEG Suite features


Easy access to BioGraph sessions


Easy normalizing of IBI data


Easy analysis of peripheral physiological data


Easy reporting options


The Rehab Suite works on two series of hardware platforms


Clinically Relevant Documentation


Comprehensive View of Patient Rehabilitation


Benefits of Biofeedback Training


Audio Visuals Can Make A World of Difference


Continuous Performance Testing (CPT)


Sports Reaction Time Training


Reaction Time Suite features


Clinically Relevant Documentation


Comprehensive View of Patient Rehabilitation


Benefits of Biofeedback Training


Audio Visuals Can Make A World of Difference


Benefits of SEMG Biofeedback


Comprehensive View of Patient Rehabilitation


Audio Visuals Can Make A World of Difference


Feedback Screens


Assessment Scripts (Protocols)


Training Scripts (Protocols)


Customize your reports


Document Your Patient's Progress with a Variety of Trending Options


Templates


DynaMap for the FlexComp Infiniti provides 7 channel sets and 57 screens for high resolution and accurate multi-channel SEMG data-acquisition.


DynaMap for the ProComp Infiniti includes 7 channel sets and 48 screens for multi-channel raw and RMS SEMG combined with up to 6 other physiological measures.


DynaMap for the ProComp+ encoder includes 7 channel sets and 37 screens for 8-channels of SEMG or a mix of 2 channels of SEMG with up to 6 other physiological measures.


Stress Control Suite